Titre | Medium term follow-up of intraocular pressure (IOP) control after needling of encapsulated blebs |
Abstract Nr. | A2051 |
But | To investigate the efficacy and safety of needling of encapsulated blebs after trabeculectomy. |
Méthodes | A retrospective chart review of 36 eyes of 36 patients who underwent filtering eye surgery (33 trabeculectomy and 3 deep sclerectomy) with subsequent needling of encapsulated bleb between January 2002 and December 2003. The mean follow-up was 19 months after the first needling. All interventions were conducted by the same surgeon. Absolute success was defined as an IOP < 18 mmHg or an IOP reduction > 20% if the preoperative IOP was 21 mmHg, without medication. Relative succes was defined as meeting these criteria with or without medication. |
Résultats | The mean interval between trabeculectomy and the 1st needling was 12.6 weeks. Repeated needling (8) was performed as clinically necessary. In 93% of the needlings 5-FU was used to prevent postoperative fibrosis. The mean IOP before the needling and at the last follow-up was respectively 21.8 and 13.6 mmHg (p<0.001) Needling was an absolute success in 50% (18/36) and a relative success in 70% (25/36). Minor complications attributed to needling occurred in 32% of the patients including self resorbing subconjunctival bleeding (4), punctatic keratitis (2), transient hypotony (3) and wound leak (4) (one patient requiring suture). A serious complication occurred in 1 case (branch vein occlusion). There were no patients who developed blebitis or endophtalmitis during the course of the study. |
Conclusion | Needling of an encapsulated bleb in the early post-operative period is a minor procedure that lowers the IOP efficiently and probably enhances medium-term bleb function. |
Nom | GILLIS |
Initiales | A |
Institut | AZ Middelheim Antwerp |
Nom | Jacobs |
Initiales | S |
Institut | KUL |
Nom | Van Malderen |
Initiales | L |
Institut | KUL |
Nom | Zeyen |
Initiales | T |
Institut | AZM + KUL |