Abstract bekijken

Deze abstract is toegekend aan sessie BSCRS Free papers Refractive
TitelHigher accuracy in astigmatic laser treatment with iris recognition
Abstract Nr.A2028
DoelBetween November 03 and 15 June 04 we treated 450 eyes with the new Zyoptix 100 laser with the irisrecognition system.
In this group 150 eyes with moderate and severe astigmatism were followed.
MethodesAll eyes were preoperatively measured by the same assistant with the Zyoptix workstation. In all patients the refractive error measured by the Zywave aberometer was used as the final treatment, without making any adjustment
from the subjective refraction.
ResultatenIn this study we followed the high and moderate astigmatic eyes and the results in this group were very promising.
The enhancement rate in this group was less then 3 % which seems to be extremely low.
ConclusieThe iris recognition eye tracker avoids torsional misalignment and improves the clinical results in astigmatic laser treatment
Auteur 1
NaamCOLLA
InitialenBMHF
InstituutOOGCENTRUM
StadTongeren
top ^